Line 372: |
Line 372: |
| * store in: store a number, string, or media object in a named box | | * store in: store a number, string, or media object in a named box |
| * start: connects action to toolbar 'Run' button | | * start: connects action to toolbar 'Run' button |
| + | |
| + | ====Media Palette==== |
| + | [[Image:TAmedia.png]] |
| + | |
| + | These are a collection of blocks used for displaying media objects, such as images from the Journal. |
| + | |
| + | ====Sensors Palette==== |
| + | [[Image:TAsensors.png]] |
| + | |
| + | * query keyboard: check for keyboard input (results are stored in the keyboard block) |
| + | * keyboard: current value of keyboard input (can be used in place of a number block) |
| + | * read pixel: push the RGB value of the pixel under the turtle onto the FILO (blue is first, red is last) |
| + | * turtle sees: the "palette color" of the pixel under the turtle |
| + | * sound: raw data from microphone ranging -32000 to 32000 |
| + | * volume: ranging 0 to 32000 |
| + | * pitch: the resolution is +-8Hz |
| + | |
| + | The OLPC XO can measure external inputs with its microphone jack: |
| + | * resistance: measurement range is 750 to 14k ohms, (OLPC XO1) and 2k ohms to open circuit (OLPC XO1.5) |
| + | * voltage: measurement range is DC 0.4V to 1.85V. (OLPC XO1) and 0.17V to 3.0V (OLPC XO1.5) |
| + | |
| + | See [[Activities/TurtleArt/Using Turtle Art Sensors]] for more details about the sensor blocks. |
| + | |
| + | ([[Activities/TurtleArt/Uso_de_TortugaArte_Sensores]] español) |
| | | |
| ====Extras Palette==== | | ====Extras Palette==== |
Line 396: |
Line 420: |
| * bottom of stack: block to denote the bottom of a collapsible stack | | * bottom of stack: block to denote the bottom of a collapsible stack |
| :: To use the collapsible-stack blocks, place them around the blocks you want to hide | | :: To use the collapsible-stack blocks, place them around the blocks you want to hide |
− |
| |
− | ====Sensors Palette====
| |
− | [[Image:TAsensors.png]]
| |
− |
| |
− | * query keyboard: check for keyboard input (results are stored in the keyboard block)
| |
− | * keyboard: current value of keyboard input (can be used in place of a number block)
| |
− | * read pixel: push the RGB value of the pixel under the turtle onto the FILO (blue is first, red is last)
| |
− | * turtle sees: the "palette color" of the pixel under the turtle
| |
− | * sound: raw data from microphone ranging -32000 to 32000
| |
− | * volume: ranging 0 to 32000
| |
− | * pitch: the resolution is +-8Hz
| |
− |
| |
− | The OLPC XO can measure external inputs with its microphone jack:
| |
− | * resistance: measurement range is 750 to 14k ohms, (OLPC XO1) and 2k ohms to open circuit (OLPC XO1.5)
| |
− | * voltage: measurement range is DC 0.4V to 1.85V. (OLPC XO1) and 0.17V to 3.0V (OLPC XO1.5)
| |
− |
| |
− | See [[Activities/TurtleArt/Using Turtle Art Sensors]] for more details about the sensor blocks.
| |
− |
| |
− | ([[Activities/TurtleArt/Uso_de_TortugaArte_Sensores]] español)
| |
| | | |
| ====Portfolio Palette==== | | ====Portfolio Palette==== |