Changes

Jump to navigation Jump to search
Line 13: Line 13:  
On the XO-1, mono data is measured, the left channel, the tip (usually the red wire). The XO-1.5, XO-1.75, XO-3 and XO-4 can read both the left and right channel. (Currently on the XO-1.75, XO-3 and XO-4 stereo input is disabled).
 
On the XO-1, mono data is measured, the left channel, the tip (usually the red wire). The XO-1.5, XO-1.75, XO-3 and XO-4 can read both the left and right channel. (Currently on the XO-1.75, XO-3 and XO-4 stereo input is disabled).
   −
The XO-1 is protected at the input by a 5V zener diode. The allowable input is -0.5V to 5V. Inputs outside this range will cause excessive current and damage. Even a single 1.5V battery can cause damage if connected reverse polarity.
+
The XO-1 is protected at the input by a 5V zener diode. [[File:XO-1_Schematics.pdf]] The allowable input is -0.5V to 5V. Inputs outside this range will cause excessive current and damage. Even a single 1.5V battery can cause damage if connected reverse polarity.
    
The XO-1.5 and XO-1.75 (XO-3 and XO-4 presumably too) are protected by a resistor,(1/16W 470 ohm SMD0402) and a pair of diodes to ground and to +3.3V which should protect -6V to +9V continuously, and up to higher voltages for shorter periods of time.  
 
The XO-1.5 and XO-1.75 (XO-3 and XO-4 presumably too) are protected by a resistor,(1/16W 470 ohm SMD0402) and a pair of diodes to ground and to +3.3V which should protect -6V to +9V continuously, and up to higher voltages for shorter periods of time.  